Комутатор Cisco DS-C9396T-48ITK9

SKU
DS-C9396T-48ITK9
Запросити ціну
EAN: 19560
Статус: Доступний під замовлення
Термін поставки: 25-35 днів
GPL price:

96400 $

MDS 9396T 32G Fibre Channel switch, with 48 active ports + 48x32G SW optics, 2 fans, 2 PSUs, port side intake

Технічні характеристики комутатора Cisco DS-C9396T-48ITK9:

Protocols

- Fibre Channel standards

- FC-PH, Revision 4.3 (ANSI INCITS 230-1994)

- FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)

- FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)

- FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)

- FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)

- FC-PI, Revision 13 (ANSI INCITS 352-2002)

- FC-PI-2, Revision 10 (ANSI INCITS 404-2006)

- FC-PI-3, Revision 4 (ANSI INCITS 460-2011)

- FC-PI-4, Revision 8 (ANSI INCITS 450-2008)

- FC-PI-5, Revision 6 (ANSI INCITS 479-2011)

- FC-PI-6 (ANSI INCITS 512-2015)

- FC-FS, Revision 1.9 (ANSI INCITS 373-2003)

- FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)

- FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)

- FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)

- FC-FS-4

- FC-LS, Revision 1.62 (ANSI INCITS 433-2007)

- FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)

- FC-LS-3, Includes revision 3.53

- FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)

- FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)

- FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)

- FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)

- FC-SW-6

- FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)

- FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)

- FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)

- FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)

- FC-GS-7, Includes revision 10.8

- FCP, Revision 12 (ANSI INCITS 269-1996)

- FCP-2, Revision 8 (ANSI INCITS 350-2003)

- FCP-3, Revision 4 (ANSI INCITS 416-2006)

- FCP-4, Revision 2b (ANSI INCITS 481-2011)

- FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)

- FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)

- FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)

- FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)

- FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)

- FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)

- FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)

- FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)

- FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)

- FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)

- FC-VI, Revision 1.84 (ANSI INCITS 357-2002)

- FC-SP, Revision 1.8 (ANSI INCITS 426-2007)

- FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)

- FAIS, Revision 1.03 (ANSI INCITS 432-2007)

- FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)

- FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)

- FC-FLA, Revision 2.7 (INCITS TR-20-1998)

- FC-PLDA, Revision 2.1 (INCITS TR-19-1998)

- FC-Tape, Revision 1.17 (INCITS TR-24-1999)

- FC-MI, Revision 1.92 (INCITS TR-30-2002)

- FC-MI-2, Revision 2.6 (INCITS TR-39-2005)

- FC-MI-3, Revision 1.03 (INCITS TR-48-2012)

- FC-DA, Revision 3.1 (INCITS TR-36-2004)

- FC-DA-2, Revision 1.06 (INCITS TR-49-2012)

- FC-MSQS, Revision 3.2 (INCITS TR-46-2011)

- Fibre Channel classes of service: Class 2, Class 3, and Class F

- Fibre Channel standard port types: E, F, and B

- Fibre Channel enhanced port types: SD, ST, and TE

- FC-NVMe

- In-band management using IP over Fibre Channel (RFC 2625)

- IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)

- Extensive IETF-standards-based TCP/IP, SNMPv3, and Remote Monitoring (RMON) MIBs

Fibre Channel ports

- Fixed switch form-factor with 96 SFP+ ports

- Entry-level 48-port preactivated base model

- Incremental ports

- 16-port upgrade license offers the option of incrementally upgrading to 64, 80, and 96 ports

Security

- VSAN fabric isolation

- Intelligent packet inspection at port level

- Hardware zoning by Access Control Lists (ACLs)

- Fibre Channel Security Protocol (FC-SP) switch-to-switch authentication

- FC-SP host-to-switch authentication

- RBAC using RADIUS, TACACS+ or LDAP Authentication, Authorization, and Accounting (AAA) functions

- Secure FTP (SFTP)

- Secure Shell Version 2 (SSHv2)

- Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)

- Control-plane security

- Cisco TrustSec payload encryption

- Secure Boot and Anti-counterfeit technology

Performance

- Port speed: 4/8/16/32-Gbps autosensing with 32 Gbps of dedicated bandwidth per port

- Aggregate bandwidth of 3 Tbps end-to-end full duplex

- Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group

- Port groups: 6 port groups of 16 ports each

- Port channel: Up to 16 load-balanced physical links grouped in one port channel

Diagnostics

- Power-On-Self-Test (POST) diagnostics

- Online Health Management System (OHMS) diagnostics

- Internal loopbacks

- SPAN

- Fibre Channel traceroute

- Fibre Channel ping

- Fibre Channel debug

- Cisco Fabric Analyzer

- Syslog

- Port-level statistics

- Link Diagnostics (E-port and F-port links)

- Read Diagnostic Parameter

Serviceability

- Configuration file management

- Call Home

- Port beaconing

- Link Cable beacon

- System LEDs

- SNMP traps for alerts

Reliability and availability

- Cisco In-Service Software Upgrade (ISSU)

- Hot-swappable, dual redundant power supplies

- Hot-swappable fan tray with switch integrated temperature and power management

- Hot-swappable SFP+ optics

- Hot swappable port expansion module

- Stateful process restart

- Any port configuration for port channels

- Fabric-based multi pathing

- Per-VSAN fabric services

- Port tracking

- VRRP for management IP interface

- FEC with HBA ports

- Buffer-to-buffer state change notification with HBA ports

Network management

- Management access through 2 out-of-band 10/100/1000 Mbps Ethernet ports

- mgmt0: 10/100/1000BASE-T port

- mgmt1: 1/10G SFP+ port #

- RS-232 serial console port

- USB power-on auto-provision port

- Access protocols

- Command-Line Interface (CLI) using the console and Ethernet port

- SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access

- Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)

- NX-API for restful access via HTTPS

- Distributed device alias service

- Network security

- Per-VSAN Role-Based Access Control (RBAC) using LDAP, RADIUS and TACACS+-based Authentication, Authorization, and Accounting (AAA) functions

- SFTP

- SSHv2 implementing AES

- SNMPv3 implementing AES

- Cisco Data Center Network Manager

Programming interfaces

- Scriptable CLI

- Cisco Prime DCNM web services API

- NX-API restful interfaces

- On-board Python interpreter

- Cisco Embedded Event Manager

- Cisco NX-OS Software scheduler

Physical dimensions (H x W x D) and weight

- Dimensions: 3.39 x 17.42 x 22.28 in. (8.61 x 44.25 x 56.59 cm), 2RU

- Rack-mountable in standard 19-inch Electronic Industries Alliance (EIA) rack

- Weight of fully configured chassis: 41.62 lb (18.88 kg)

Power

- 80 Plus Platinum certified power supplies

- Power supply

- 1200W AC/ HVAC/ HVDC Bidirectional airflow (2 per switch)

- Power grid redundancy (1+1)

- Two power cords

- Standard CAB-HVAC-C14-2M IEC C14 to Saf-d-grid connector on the power supply receptacle

- See Table 6 for configurable AC power cords that connect to AC sockets specific to regions

- AC input: 90V to 305V

- DC input: 192V to 400V

- Frequency: 50 to 60 Hz (nominal)

- Typical power consumption

- 246W for Idle 96-port switch with (1+1) PSU redundancy without optics modules

- 330W for 96-port switch with 48 32G optics modules under typical conditions

- 555W for 96-port switch with 96 32G optics modules under typical conditions

- Airflow

- 2 fan trays as standard configuration

- Back to front (toward ports) using port-side exhaust fans

- Front to back (inward from ports) using port-side intake fans

- Maximum 255 Cubic Feet per Minute (CFM)

- Nominal 110 CFM (25C)

Temperature range

- Temperature, ambient operating:

- 32° to 104°F (0° to 40°C)

- Temperature, ambient nonoperating and storage: -40° to 158°F (-40° to 70°C)

- Relative humidity, ambient (noncondensing) operating: 10 to 90%

- Relative humidity, ambient (noncondensing) non-operating and storage: 10 to 95%

- Altitude, operating: -197 to 6500 ft (-60 to 2000m)

Approvals and compliance

- Safety compliance

- CE Marking

- UL 60950

- CAN/CSA-C22.2 No. 60950

- EN 60950

- IEC 60950

- TS 001

- AS/NZS 3260

- IEC60825

- EN60825

- 21 CFR 1040

- EMC compliance

- FCC Part 15 (CFR 47) Class A

- ICES-003 Class A

- EN 55022 Class A

- CISPR 22 Class A

- AS/NZS 3548 Class A

- VCCI Class A

- EN 55024

- EN 50082-1

- EN 61000-6-1

- EN 61000-3-2

- EN 61000-3-3

Fabric services

- Name server

- Registered State Change Notification (RSCN)

- Login services

- Fabric Configuration Server (FCS)

- Broadcast

- In-order delivery

Advanced functions

- VSAN

- IVR

- Port channel with multipath load balancing

- Flow-based and zone-based QoS

Код товару19560
ВиробникCisco