Specifications
|
Aruba Instant On 1430 5G Switch (R8R44A)
|
Aruba Instant On 1430 8G Switch (R8R45A)
|
Aruba Instant On 1430 8G Class4 PoE 64W Switch (R8R46A)
|
Aruba Instant On 1430 16G Switch (R8R47A)
|
Aruba Instant On 1430 16G Class4 PoE 124W Switch (R8R48A)
|
Aruba Instant On 1430 24G Switch (R8R49A)
|
Aruba Instant On 1430 26G 2SFP Switch (R8R50A)
|
I/O ports and slots
|
|
5 RJ-45 autosensing 10/100/1000 ports
(IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASET/100BASE-TX: half or full; 1000BASE-T: full only
|
8 RJ-45 autosensing 10/100/1000 ports
(IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASET/100BASE-TX: half or full; 1000BASE-T: full only
|
8 RJ-45 autosensing 10/100/1000 Class 4 PoE ports
(IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASET/100BASE-TX: half or full; 1000BASE-T: full only
|
16 RJ-45 autosensing 10/100/1000 ports
(IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASET/100BASE-TX: half or full; 1000BASE-T: full only
|
16 RJ-45 autosensing 10/100/1000 Class 4 PoE ports
(IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASET/100BASE-TX: half or full; 1000BASE-T: full only
|
24 RJ-45 autosensing 10/100/1000 ports
(IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASET/100BASE-TX: half or full; 1000BASE-T: full only
|
26 RJ-45 autosensing 10/100/1000 ports
(IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 10BASET/100BASE-TX: half or full; 1000BASE-T: full only
2 SFP 1GbE ports
|
Physical Characteristics
|
Dimensions
|
93(d) x 116(w) x 26(h) mm
|
138(d) x 157(w) x 37(h) mm
|
150(d) x 177(w) x 37(h) mm
|
258(d) x 275(w) x 44(h) mm
|
260(d) x 275(w) x 44(h) mm
|
225(d) x 340(w) x 44(h) mm
|
225(d) x 388(w) x 44(h) mm
|
Weight
|
0.60 lb (0.27 kg)
|
1.30 lb (0.59 kg)
|
1.70 lb (0.77 kg)
|
3.80 lb (01.72 kg)
|
4.60 lb (2.09 kg)
|
4.20 lb (1.91 kg)
|
5.00 lb (2.27 kg)
|
Processor and Memory
|
|
2Kb EEPROM; Packet buffer size: 1.0 Mb
|
128Kb EEPROM; Packet buffer size: 2.0 Mb
|
128Kb EEPROM; Packet buffer size: 2.0 Mb
|
128Kb EEPROM; Packet buffer size: 2.0 Mb
|
128Kb EEPROM; Packet buffer size: 2.0 Mb
|
128Kb EEPROM; Packet buffer size: 2.0 Mb
|
32Mb Flash; Packet buffer size: 12.0 Mb
|
Performance
|
100 Mb latency
|
< 3.81μSec
|
< 2.7 μSec
|
< 2.7 μSec
|
< 2.7 μSec
|
< 2.7 μSec
|
< 2.7 μSec
|
< 5.21 μSec
|
1000 Mb latency
|
< 0.93 μSec
|
< 1.80 μSec
|
< 1.80 μSec
|
< 1.80 μSec
|
< 1.80 μSec
|
< 1.80 μSec
|
< 2.90 μSec
|
Throughput (Mpps)
|
7.44 Mpps
|
11.90 Mpps
|
11.90 Mpps
|
23.80 Mpps
|
23.80 Mpps
|
35.71 Mpps
|
41.68 Mpps
|
Capacity
|
10 Gbps
|
16 Gbps
|
16 Gbps
|
32 Gbps
|
32 Gbps
|
48 Gbps
|
56 Gbps
|
MAC address table size
|
8192 entries
|
8192 entries
|
8192 entries
|
8192 entries
|
8192 entries
|
8192 entries
|
16384 entries
|
Reliability MTBF (years)
|
525.8
|
416.2
|
131.1
|
269.8
|
126.1
|
199.5
|
171.9
|
Environment
|
Operating temperature
|
32°F to 104°F (0°C to 40°C)
|
32°F to 104°F (0°C to 40°C)
|
32°F to 104°F (0°C to 40°C)
|
32°F to 104°F (0°C to 40°C)
|
32°F to 104°F (0°C to 40°C)
|
32°F to 104°F (0°C to 40°C)
|
32°F to 104°F (0°C to 40°C)
|
Operating relative humidity
|
15% to 95% @ 104°F (40°C) non-condensing
|
15% to 95% @ 104°F (40°C) non-condensing
|
15% to 95% @ 104°F (40°C) non-condensing
|
15% to 95% @ 104°F (40°C) non-condensing
|
15% to 95% @ 104°F (40°C) non-condensing
|
15% to 95% @ 104°F (40°C) non-condensing
|
15% to 95% @ 104°F (40°C) non-condensing
|
Nonoperating/ storage temperature
|
-40°F to 158°F (-40°C to 70°C) up to 15000 ft
|
-40°F to 158°F (-40°C to 70°C) up to 15000 ft
|
-40°F to 158°F (-40°C to 70°C) up to 15000 ft
|
-40°F to 158°F (-40°C to 70°C) up to 15000 ft
|
-40°F to 158°F (-40°C to 70°C) up to 15000 ft
|
-40°F to 158°F (-40°C to 70°C) up to 15000 ft
|
-40°F to 158°F (-40°C to 70°C) up to 15000 ft
|
Nonoperating/ storage relative humidity
|
15% to 90% @ 149°F (65°C) non-condensing
|
15% to 90% @ 149°F (65°C) non-condensing
|
15% to 90% @ 149°F (65°C) non-condensing
|
15% to 90% @ 149°F (65°C) non-condensing
|
15% to 90% @ 149°F (65°C) non-condensing
|
15% to 90% @ 149°F (65°C) non-condensing
|
15% to 90% @ 149°F (65°C) non-condensing
|
Altitude
|
up to 10,000 ft (3 km)
|
up to 10,000 ft (3 km)
|
up to 10,000 ft (3 km)
|
up to 10,000 ft (3 km)
|
up to 10,000 ft (3 km)
|
up to 10,000 ft (3 km)
|
up to 10,000 ft (3 km)
|
Acoustics
|
|
Fanless
|
Fanless
|
Fanless
|
Fanless
|
Fanless
|
Fanless
|
Fanless
|
Electrical Characteristics
|
Frequency
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
AC voltage
|
100-240VAC
|
100-240VAC
|
100-240VAC
|
100-127VAC / 200- 240VAC
|
100-127VAC / 200- 240VAC
|
100-127VAC / 200- 240VAC
|
100-127VAC / 200- 240VAC
|
Current
|
0.3A (12VDC - 1A)
|
0.3A (12VDC - 1A)
|
2A (54VDC - 1.58A)
|
0.2A/0.2A
|
1.7A /0.8A
|
0.3A / 0.2A
|
0.4A / 0.3A
|
Maximum power rating
|
12W
|
12W
|
90W
|
7.9W
|
147W
|
11.7W
|
16.4W
|
Idle power
|
1W
|
1.7W
|
4.1W
|
2.3W
|
5W
|
3.2W
|
8W
|
PoE power
|
—
|
—
|
64W Class 4 PoE
|
—
|
124W Class 4 PoE
|
—
|
—
|
Power supply
|
External Power Adapter
|
External Power Adapter
|
External Power Adapter
|
Internal Power Supply
|
Internal Power Supply
|
Internal Power Supply
|
Internal Power Supply
|
Safety
|
|
EN/IEC 60950- 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
EN/IEC 62368-1, 2nd. & 3rd. Ed.
UL 62368-1, 3rd. Ed.
CAN/CSA C22.2 No. 62368-1, 3rd. Ed.
EN/IEC 60825- 1:2014 Class 1
|
EN/IEC 60950- 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
EN/IEC 62368-1, 2nd. & 3rd. Ed.
UL 62368-1, 3rd. Ed.
CAN/CSA C22.2 No. 62368-1, 3rd. Ed
EN/IEC 60825- 1:2014 Class 1
|
EN/IEC 60950- 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
EN/IEC 62368-1, 2nd. & 3rd. Ed.
UL 62368-1, 3rd. Ed.
CAN/CSA C22.2 No. 62368-1, 3rd. Ed
EN/IEC 60825- 1:2014 Class 1
|
EN/IEC 60950- 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
EN/IEC 62368-1, 2nd. & 3rd. Ed.
UL 62368-1, 3rd. Ed.
CAN/CSA C22.2 No. 62368-1, 3rd. Ed
EN/IEC 60825- 1:2014 Class 1
|
EN/IEC 60950- 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
EN/IEC 62368-1, 2nd. & 3rd. Ed.
UL 62368-1, 3rd. Ed.
CAN/CSA C22.2 No. 62368-1, 3rd. Ed
EN/IEC 60825- 1:2014 Class 1
|
EN/IEC 60950- 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
EN/IEC 62368-1, 2nd. & 3rd. Ed.
UL 62368-1, 3rd. Ed.
CAN/CSA C22.2 No. 62368-1, 3rd. Ed
EN/IEC 60825- 1:2014 Class 1
|
EN/IEC 60950- 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
EN/IEC 62368-1, 2nd. & 3rd. Ed.
UL 62368-1, 3rd. Ed.
CAN/CSA C22.2 No. 62368-1, 3rd. Ed
EN/IEC 60825- 1:2014 Class 1
|
Emissions
|
|
EN 55032:2015/CISPR 32, Class B
FCC CFR 47 Part 15: 2018, Class B
CES-003, Class B
VCCI-32, Class B
CNS 13438, Class B
KS C 9832, Class B
AS/NZS CISPR 32, Class B
|
EN 55032:2015/CISPR 32, Class B
FCC CFR 47 Part 15: 2018, Class B
CES-003, Class B
VCCI-32, Class B
CNS 13438, Class B
KS C 9832, Class B
AS/NZS CISPR 32, Class B
|
EN 55032:2015/CISPR 32, Class B
FCC CFR 47 Part 15: 2018, Class B
CES-003, Class B
VCCI-32, Class B
CNS 13438, Class B
KS C 9832, Class B
AS/NZS CISPR 32, Class B
|
EN 55032:2015/CISPR 32, Class B
FCC CFR 47 Part 15: 2018, Class B
CES-003, Class B
VCCI-32, Class B
CNS 13438, Class B
KS C 9832, Class B
AS/NZS CISPR 32, Class B
|
EN 55032:2015/CISPR 32, Class B
FCC CFR 47 Part 15: 2018, Class B
CES-003, Class B
VCCI-32, Class B
CNS 13438, Class B
KS C 9832, Class B
AS/NZS CISPR 32, Class B
|
EN 55032:2015/CISPR 32, Class B
FCC CFR 47 Part 15: 2018, Class B
CES-003, Class B
VCCI-32, Class B
CNS 13438, Class B
KS C 9832, Class B
AS/NZS CISPR 32, Class B
|
EN 55032:2015/CISPR 32, Class B
FCC CFR 47 Part 15: 2018, Class B
CES-003, Class B
VCCI-32, Class B
CNS 13438, Class B
KS C 9832, Class B
AS/NZS CISPR 32, Class B
|
Immunity
|
Generic
|
BS/EN 55035, CISPR 35, KS C 9835
|
BS/EN 55035, CISPR 35, KS C 9835
|
BS/EN 55035, CISPR 35, KS C 9835
|
BS/EN 55035, CISPR 35, KS C 9835
|
BS/EN 55035, CISPR 35, KS C 9835
|
BS/EN 55035, CISPR 35, KS C 9835
|
BS/EN 55035, CISPR 35, KS C 9835
|
EN
|
EN 55035, CISPR 35
|
EN 55035, CISPR 35
|
EN 55035, CISPR 35
|
EN 55035, CISPR 35
|
EN 55035, CISPR 35
|
EN 55035, CISPR 35
|
EN 55035, CISPR 35
|
ESD
|
EN/IEC 61000-4-2
|
EN/IEC 61000-4-2
|
EN/IEC 61000-4-2
|
EN/IEC 61000-4-2
|
EN/IEC 61000-4-2
|
EN/IEC 61000-4-2
|
EN/IEC 61000-4-2
|
Radiated
|
EN/IEC 61000-4-3
|
EN/IEC 61000-4-3
|
EN/IEC 61000-4-3
|
EN/IEC 61000-4-3
|
EN/IEC 61000-4-3
|
EN/IEC 61000-4-3
|
EN/IEC 61000-4-3
|
EFT/Burst
|
EN/IEC 61000-4-4
|
EN/IEC 61000-4-4
|
EN/IEC 61000-4-4
|
EN/IEC 61000-4-4
|
EN/IEC 61000-4-4
|
EN/IEC 61000-4-4
|
EN/IEC 61000-4-4
|
Surge
|
EN/IEC 61000-4-5
|
EN/IEC 61000-4-5
|
EN/IEC 61000-4-5
|
EN/IEC 61000-4-5
|
EN/IEC 61000-4-5
|
EN/IEC 61000-4-5
|
EN/IEC 61000-4-5
|
Conducted
|
EN/IEC 61000-4-6
|
EN/IEC 61000-4-6
|
EN/IEC 61000-4-6
|
EN/IEC 61000-4-6
|
EN/IEC 61000-4-6
|
EN/IEC 61000-4-6
|
EN/IEC 61000-4-6
|
Power frequency magnetic field
|
EN/IEC 61000-4-8
|
EN/IEC 61000-4-8
|
EN/IEC 61000-4-8
|
EN/IEC 61000-4-8
|
EN/IEC 61000-4-8
|
EN/IEC 61000-4-8
|
EN/IEC 61000-4-8
|
Voltage dips and interruptions
|
EN/IEC 61000-4-11
|
EN/IEC 61000-4-11
|
EN/IEC 61000-4-11
|
EN/IEC 61000-4-11
|
EN/IEC 61000-4-11
|
EN/IEC 61000-4-11
|
EN/IEC 61000-4-11
|
Harmonics
|
EN/IEC 61000-3-2
|
EN/IEC 61000-3-2
|
EN/IEC 61000-3-2
|
EN/IEC 61000-3-2
|
EN/IEC 61000-3-2
|
EN/IEC 61000-3-2
|
EN/IEC 61000-3-2
|
Flicker
|
EN /IEC 61000-3-3
|
EN /IEC 61000-3-3
|
EN /IEC 61000-3-3
|
EN /IEC 61000-3-3
|
EN /IEC 61000-3-3
|
EN /IEC 61000-3-3
|
EN /IEC 61000-3-3
|
Device Management
|
|
Unmanaged
|
Unmanaged
|
Unmanaged
|
Unmanaged
|
Unmanaged
|
Unmanaged
|
Unmanaged
|
Mounting
|
Mounting positions and supported racking
|
Supports table-top mounting
Supports wall-mounting with ports facing either up or down using base surface mounting holes
Supports undertable mounting using base surface mounting holes
|
Supports table-top mounting
Supports wall-mounting with ports facing either up or down using base surface mounting holes
Supports undertable mounting using base surface mounting holes
|
Mounts in an EIA standard 19 in telco rack or equipment cabinet. 2-post rack kit included
Supports table-top mounting
Supports rack-mounting using the brackets provided
Supports wallmounting with ports facing either up or down using either the base surface mounting holes, or the brackets provided
Supports undertable mounting using the brackets provided
Must be mounted top surface up. To prevent possible impact to longterm reliability, product should not be mounted upside-down
|
Mounts in an EIA standard 19 in telco rack or equipment cabinet. 2-post rack kit included
Supports table-top mounting
Supports rack-mounting using the brackets provided
Supports wallmounting with ports facing either up or down using either the base surface mounting holes, or the brackets provided
Supports undertable mounting using the brackets provided
Must be mounted top surface up. To prevent possible impact to longterm reliability, product should not be mounted upside-down
|
Mounts in an EIA standard 19 in telco rack or equipment cabinet. 2-post rack kit included
Supports table-top mounting
Supports rack-mounting using the brackets provided
Supports wallmounting with ports facing either up or down using either the base surface mounting holes, or the brackets provided
Supports undertable mounting using the brackets provided
Must be mounted top surface up. To prevent possible impact to longterm reliability, product should not be mounted upside-down
|
Mounts in an EIA standard 19 in telco rack or equipment cabinet. 2-post rack kit included
Supports table-top mounting
Supports rack-mounting using the brackets provided
Supports wallmounting with ports facing either up or down using either the base surface mounting holes, or the brackets provided
Supports undertable mounting using the brackets provided
Must be mounted top surface up. To prevent possible impact to longterm reliability, product should not be mounted upside-down
|
Mounts in an EIA standard 19 in telco rack or equipment cabinet. 2-post rack kit included
Supports table-top mounting
Supports rack-mounting using the brackets provided
Supports wallmounting with ports facing either up or down using either the base surface mounting holes, or the brackets provided
Supports undertable mounting using the brackets provided
Must be mounted top surface up. To prevent possible impact to longterm reliability, product should not be mounted upside-down
|
Transceivers
|
|
|
Aruba 1G SFP LC LX 10km SMF Transceiver (J4859D)
Aruba Instant On 1G SFP LC SX 500m OM2 MMF Transceiver (R9D16A)
|