Комутатор Cisco DS-C9132T-8PMETK9

SKU
DS-C9132T-8PMETK9
307 230,00 грн
EAN: 19534
Статус: Доступний під замовлення
Термін поставки: 25-35 днів
GPL price:

13300 $

MDS 9132T 32G FC switch, w/ 8 active ports + 8x32G SW Optics, 2 Fans, 1 PSUs, Port Side Exhaust

Технічні характеристики комутатора Cisco DS-C9132T-8PMETK9:

Protocols

  • Fibre Channel standards
  • FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
  • FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
  • FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
  • FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
  • FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
  • FC-PI, Revision 13 (ANSI INCITS 352-2002)
  • FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
  • FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
  • FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
  • FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
  • FC-PI-6 (ANSI INCITS 512-2015)
  • FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
  • FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
  • FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
  • FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
  • FC-FS-4
  • FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
  • FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
  • FC-LS-3, Includes revision 3.53
  • FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
  • FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
  • FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
  • FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
  • FC-SW-6
  • FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
  • FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
  • FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)
  • FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)
  • FC-GS-7, Includes revision 10.8
  • FCP, Revision 12 (ANSI INCITS 269-1996)
  • FCP-2, Revision 8 (ANSI INCITS 350-2003)
  • FCP-3, Revision 4 (ANSI INCITS 416-2006)
  • FCP-4, Revision 2b (ANSI INCITS 481-2011)
  • FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
  • FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
  • FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
  • FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
  • FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)
  • FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)
  • FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
  • FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
  • FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
  • FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
  • FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
  • FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
  • FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
  • FAIS, Revision 1.03 (ANSI INCITS 432-2007)
  • FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
  • FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
  • FC-FLA, Revision 2.7 (INCITS TR-20-1998)
  • FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
  • FC-Tape, Revision 1.17 (INCITS TR-24-1999)
  • FC-MI, Revision 1.92 (INCITS TR-30-2002)
  • FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
  • FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
  • FC-DA, Revision 3.1 (INCITS TR-36-2004)
  • FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
  • FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
  • Fibre Channel classes of service: Class 2, Class 3, and Class F
  • Fibre Channel standard port types: E, F, and B
  • Fibre Channel enhanced port types: SD, ST, and TE
  • NVMe/FC
  • In-band management using IP over Fibre Channel (RFC 2625)
  • IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)
  • Extensive IETF-standards-based TCP/IP, SNMPv3, and Remote Monitoring (RMON) MIBs

Fibre Channel ports

  • Fixed switch form factor with 16 SFP+ ports base and one 16 SFP+ port expansion slot
  • Entry-level 8-port preactivated base model with flexibility to turn on any 8 ports
  • Incremental ports

- On the 8-port base model, with the 8-Port On- Demand Activation license to activate up to 16 ports on the base switch

- On the 8-port base model, with the 16-port expansion module to activate up to 24 ports

- On the 16-port configuration, with the 16-port expansion module to activate up to 32 ports

- On the 24-port configuration, with the 8-Port On- Demand Activation license to activate up to 32 ports

Security

  • VSAN fabric isolation
  • Intelligent packet inspection @ port level
  • Hardware zoning by Access Control Lists (ACLs)
  • FC-SP switch-to-switch authentication
  • FC-SP host-to-switch authentication
  • RBAC using RADIUS, TACACS+ or LDAP Authentication, Authorization, and Accounting (AAA) functions
  • Secure FTP (SFTP)
  • Secure Shell Version 2 (SSHv2)
  • Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)
  • Control-plane security
  • Cisco TrustSec payload encryption
  • Secure Boot and Anti-counterfeit technology

Performance

  • Port speed: 4/8/16/32-Gbps autosensing with 32 Gbps of dedicated bandwidth per port
  • Aggregate bandwidth of 1024 Gbps end-to-end full duplex
  • Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group
  • Port channel: Up to 16 load-balanced physical links grouped in one port channel

Diagnostics

  • Power-on-Self-Test (POST) diagnostics
  • Online Health Management System (OHMS) diagnostics
  • Internal loopbacks
  • SPAN
  • Fibre Channel traceroute
  • Fibre Channel ping
  • Fibre Channel debug
  • Cisco Fabric Analyzer
  • Syslog
  • Port-level statistics
  • Link Diagnostics ( ISL Diagnostics and HBA Diagnostics)
  • Read Diagnostic Parameter

Serviceability

  • Configuration file management
  • Call Home
  • Port beaconing
  • Link Cable Beacon
  • System LEDs
  • SNMP traps for alerts

Reliability and availability

  • Cisco In-Service Software Upgrade (ISSU)
  • Hot-swappable, dual redundant power supplies
  • Hot-swappable fan tray with switch integrated temperature and power management
  • Hot-swappable SFP+ optics
  • Stateful process restart
  • Any port configuration for port channels
  • Fabric-based multi pathing
  • Per-VSAN fabric services
  • Port tracking
  • VRRP for management IP interface

Network management

  • Management access through 2 out-of-band 10/100/1000 Mbps Ethernet ports

- mgmt0: 10/100/1000BASE-T port

- mgmt1: 10/100/1000BASE-T port

  • RS-232 serial console port
  • USB power-on auto-provision port
  • Access protocols
  • Command-Line Interface (CLI) using the console and Ethernet port
  • SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access
  • Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
  • NX-API for restful access via HTTPS
  • Distributed device alias service
  • Network security
  • Per-VSAN Role-Based Access Control (RBAC) using LDAP, RADIUS and TACACS+-based Authentication, Authorization, and Accounting (AAA) functions
  • SFTP
  • SSHv2 implementing AES
  • SNMPv3 implementing AES
  • Cisco Data Center Network Manager

Programming interfaces

  • Scriptable CLI
  • Cisco Prime DCNM web services API
  • NX-API restful interfaces
  • On-board Python interpreter
  • Cisco Embedded Event Manager
  • Cisco NX-OS Software scheduler

Physical dimensions (HxWxD) and weight

  • 1RU (1.72 inches x 17.3 inches x 20.11 inches) excluding Power Supply Unit (PSU) and fan tray handles
  • 9.1 kg with 16 activated ports
  • 9.82 kg with all 32 activated ports

Power

  • 80 Plus Platinum certified power supplies
  • Power supply options

- 650W AC in base model, port-side exhaust variant (up to 2 per switch)

- 650W AC in base model, port-side intake variant (up to 2 per switch)

  • Power cord

- IEC60320 C14 plug on 650W power supply connecting to a notched C15 socket connector (check Table 6 for power cords specific to regions)

  • AC input: 100 to 240V AC (10% range)
  • Frequency: 50 to 60 Hz (nominal)
  • Typical power consumption

- 72W for idle base switch with 16 ports activated without SFPs

- 43W for idle expansion module with 16 ports activated without SFPs

- 80W for 8 ports activated with 32G SFPs with traffic at 25°C

  • Airflow

- Back to front (toward ports) using port-side exhaust fans

- Front to back (inward from ports) using port-side intake fans

- 50 Cubic Feet per Minute (CFM) through system fan assembly at 25°C

- 100 CFM maximum

Temperature range

  • Temperature, ambient operating:

- 32 to 104°F (0 to 45°C) with port-side exhaust airflow variant

- 32 to 131°F (0 to 55°C) with port-side intake airflow variant

  • Temperature, ambient nonoperating and storage: -40 to 158°F (-40 to 70°C)
  • Relative humidity, ambient (noncondensing) operating: 10 to 90%
  • Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%
  • Altitude, operating: -197 to 6500 ft (-60 to 2000m)

Approvals and compliance

  • Safety compliance
  • CE Marking
  • UL 60950
  • CAN/CSA-C22.2 No. 60950
  • EN 60950
  • IEC 60950
  • TS 001
  • AS/NZS 3260
  • IEC60825
  • EN60825
  • 21 CFR 1040
  • EMC compliance
  • FCC Part 15 (CFR 47) Class A
  • ICES-003 Class A
  • EN 55022 Class A
  • CISPR 22 Class A
  • AS/NZS 3548 Class A
  • VCCI Class A
  • EN 55024
  • EN 50082-1
  • EN 61000-6-1
  • EN 61000-3-2
  • EN 61000-3-3

Fabric services

  • Name server
  • Registered State Change Notification (RSCN)
  • Login services
  • Fabric Configuration Server (FCS)
  • Broadcast
  • In-order delivery

Advanced functions

  • VSAN
  • IVR
  • Port channel with multipath load balancing
  • Flow-based and zone-based QoS
Код товару19534
ВиробникCisco