|
|
|
|
|
SRX5400
|
SRX5600
|
SRX5800
|
Maximum Performance and Capacity1
|
Junos OS version tested
|
Junos OS 15.1x49
|
Junos OS 15.1x49
|
Junos OS 15.1x49
|
Firewall performance, large packet (with Express Path)
|
480 Gbps
|
960 Gbps
|
2 Tbps
|
Firewall performance, IMIX (with Express Path)
|
468 Gbps
|
936 Gbps
|
2 Tbps
|
Firewall performance
|
65 Gbps
|
130 Gbps
|
320 Gbps
|
Latency (with Express Path)
|
~7-11mksec
|
~7-11mksec
|
~7-11mksec
|
Maximum AES256+SHA-1 VPN performance
|
35 Gbps
|
100 Gbps
|
200 Gbps
|
Maximum IPS performance
|
22 Gbps
|
50 Gbps
|
100 Gbps
|
Maximum concurrent sessions2
|
42 Million
|
114 Million
|
230 Million
|
New sessions/second (sustained, tcp, 3way)
|
420
|
1 Million
|
2 Million
|
Maximum user supported
|
Unrestricted
|
Unrestricted
|
Unrestricted
|
Network Connectivity
|
Maximum available slots for IOCs
|
2
|
5
|
11
|
IOC3 options (SRX5K-MPC3-100G10G; SRX5K-MPC3-40G10G)
|
2x100GbE CFP2 and 4x10GbE SFP+ or 6x40GbE QSFP+ and 24x10GbE SFP+
|
IOC2 options (SRX5K-MPC)
|
Supports 2 pluggable MIC modules per card. MICs can be mixed from the following models: 20 x 1GbE SFP 10 x 10GbE SFP+ 2 x 40GbE QSFP 1 x 100GbE CFP
|
IOC options (SRX5K-40GE-SFP; SRX5K-4XGE-XFP)
|
|
40 x 1GbE SFP or 4 x 10GbE XFP
|
Flex IOC options (SRX5K-FPC-IOC)
|
|
Supports 2 pluggable IOC modules per card. IOCs can be mixed from the following models: 16 x 1GbE RJ-45 16 x 1GbE SFP 4 x 10GbE XSP
|
Virtualization
|
Maximum virtual firewalls with data plane traffic segregation (virtual routers)
|
2
|
2
|
2
|
Maximum security zones
|
2
|
2
|
2
|
Maximum virtual firewalls with data plane and administrative separation (logical systems)
|
32
|
32
|
32
|
Additional off-platform virtual firewall option with Firefly (VM based)
|
Unlimited
|
Unlimited
|
Unlimited
|
Maximum number of VLANs
|
4,096
|
4,096
|
4,096
|
Routing
|
BGP instances
|
1
|
1
|
1
|
BGP peers
|
2
|
2
|
2
|
BGP routes
|
1 Million4
|
1 Million4
|
1 Million4
|
OSPF instances
|
400
|
400
|
400
|
OSPF routes
|
1 Million
|
1 Million
|
1 Million
|
RIP v1/v2 instances
|
50
|
50
|
50
|
RIP v2 table size
|
30
|
30
|
30
|
Dynamic routing
|
Yes
|
Yes
|
Yes
|
Static routes
|
Yes
|
Yes
|
Yes
|
Source-based routing
|
Yes
|
Yes
|
Yes
|
Policy-based routing
|
Yes
|
Yes
|
Yes
|
Equal cost multipath (ECMP)
|
Yes
|
Yes
|
Yes
|
Reverse path forwarding (RPF)
|
Yes
|
Yes
|
Yes
|
Multicast
|
Yes
|
Yes
|
Yes
|
Certifications
|
Safety certifications
|
Yes
|
Yes
|
Yes
|
Electromagnetic Compatibility (EMC) certifications
|
Yes
|
Yes
|
Yes
|
RoHS2 Compliant (European Directive 2011/65/EU)
|
Yes
|
Yes
|
Yes
|
Designed for NEBS Level 3
|
Yes
|
Yes
|
Yes
|
NIST FIPS-140-2 Level 2
|
In progress
|
Yes (with Junos OS 10.4R4)
|
Yes (with Junos OS 10.4R4)
|
Common Criteria NDPP+TFFW EP + VPN EP
|
Yes (with Junos OS 12.1x46)
|
Yes (with Junos OS 12.1x46)
|
Yes (with Junos OS 12.1x46)
|
ICSA Network Firewall
|
Yes
|
Yes
|
Yes
|
ICSA IPsec
|
Yes
|
Yes
|
Yes
|
USGv6
|
Yes (with Junos OS 12.1x46)
|
Yes (with Junos OS 12.1x46)
|
Yes (with Junos OS 12.1x46)
|
Dimensions and Power
|
Dimensions (W x H x D)
|
17.45 x 8.7 x 24.5 in
|
17.5 x 14 x 23.8 in
|
17.5 x 27.8 x 23.5 in
|
(44.3 x 22.1 x 62.2 cm)
|
(44.5 x 35.6 x 60.5 cm)
|
(44.5 x 70.5 x 59.7 cm)
|
Weight
|
Fully configured 128 lb (58.1 kg)
|
Fully Configured: 180 lb (81.7 kg)
|
Fully Configured: 334 lb (151.6 kg)
|
Power supply (AC)
|
100 to 240 VAC
|
100 to 240 VAC
|
200 to 240 VAC
|
Power supply (DC)
|
-40 to -60 VDC
|
-40 to -60 VDC
|
-40 to -60 VDC
|
Maximum power
|
4,100 watts (AC high capacity)
|
4,100 watts (AC high capacity)
|
8,200 watts (AC high capacity)
|
Typical Power
|
1540 watts
|
2440 watts
|
5015 watts
|
Environmental
|
Operating temperature – long term
|
41° to 104° F (5° to 40° C)
|
41° to 104° F (5° to 40° C)
|
41° to 104° F (5° to 40° C)
|
Operating temperature – short term8
|
23° to 131° F (-5° to 55° C)
|
23° to 131° F (-5° to 55° C)
|
23° to 131° F (-5° to 55° C)
|
Humidity – long term
|
5% to 85% noncondensing
|
5% to 85% noncondensing
|
5% to 85% noncondensing
|
Humidity – short term8
|
5% to 93% noncondensing but not to exceed 0.026kg water/kg of dry air
|
5% to 93% noncondensing but not to exceed 0.026kg water/kg of dry air
|
5% to 93% noncondensing but not to exceed 0.026kg water/kg of dry air
|