| SRX5400 | SRX5600 | SRX5800 |
Maximum Performance and Capacity1 |
Junos OS version tested | Junos OS 15.1x49 | Junos OS 15.1x49 | Junos OS 15.1x49 |
Firewall performance, large packet (with Express Path) | 480 Gbps | 960 Gbps | 2 Tbps |
Firewall performance, IMIX (with Express Path) | 468 Gbps | 936 Gbps | 2 Tbps |
Firewall performance | 65 Gbps | 130 Gbps | 320 Gbps |
Latency (with Express Path) | ~7-11mksec | ~7-11mksec | ~7-11mksec |
Maximum AES256+SHA-1 VPN performance | 35 Gbps | 100 Gbps | 200 Gbps |
Maximum IPS performance | 22 Gbps | 50 Gbps | 100 Gbps |
Maximum concurrent sessions2 | 42 Million | 114 Million | 230 Million |
New sessions/second (sustained, tcp, 3way) | 420 | 1 Million | 2 Million |
Maximum user supported | Unrestricted | Unrestricted | Unrestricted |
Network Connectivity |
Maximum available slots for IOCs | 2 | 5 | 11 |
IOC3 options (SRX5K-MPC3-100G10G; SRX5K-MPC3-40G10G) | 2x100GbE CFP2 and 4x10GbE SFP+ or 6x40GbE QSFP+ and 24x10GbE SFP+ |
IOC2 options (SRX5K-MPC) | Supports 2 pluggable MIC modules per card. MICs can be mixed from the following models: 20 x 1GbE SFP 10 x 10GbE SFP+ 2 x 40GbE QSFP 1 x 100GbE CFP |
IOC options (SRX5K-40GE-SFP; SRX5K-4XGE-XFP) | | 40 x 1GbE SFP or 4 x 10GbE XFP |
Flex IOC options (SRX5K-FPC-IOC) | | Supports 2 pluggable IOC modules per card. IOCs can be mixed from the following models: 16 x 1GbE RJ-45 16 x 1GbE SFP 4 x 10GbE XSP |
Virtualization |
Maximum virtual firewalls with data plane traffic segregation (virtual routers) | 2 | 2 | 2 |
Maximum security zones | 2 | 2 | 2 |
Maximum virtual firewalls with data plane and administrative separation (logical systems) | 32 | 32 | 32 |
Additional off-platform virtual firewall option with Firefly (VM based) | Unlimited | Unlimited | Unlimited |
Maximum number of VLANs | 4,096 | 4,096 | 4,096 |
Routing |
BGP instances | 1 | 1 | 1 |
BGP peers | 2 | 2 | 2 |
BGP routes | 1 Million4 | 1 Million4 | 1 Million4 |
OSPF instances | 400 | 400 | 400 |
OSPF routes | 1 Million | 1 Million | 1 Million |
RIP v1/v2 instances | 50 | 50 | 50 |
RIP v2 table size | 30 | 30 | 30 |
Dynamic routing | Yes | Yes | Yes |
Static routes | Yes | Yes | Yes |
Source-based routing | Yes | Yes | Yes |
Policy-based routing | Yes | Yes | Yes |
Equal cost multipath (ECMP) | Yes | Yes | Yes |
Reverse path forwarding (RPF) | Yes | Yes | Yes |
Multicast | Yes | Yes | Yes |
Certifications |
Safety certifications | Yes | Yes | Yes |
Electromagnetic Compatibility (EMC) certifications | Yes | Yes | Yes |
RoHS2 Compliant (European Directive 2011/65/EU) | Yes | Yes | Yes |
Designed for NEBS Level 3 | Yes | Yes | Yes |
NIST FIPS-140-2 Level 2 | In progress | Yes (with Junos OS 10.4R4) | Yes (with Junos OS 10.4R4) |
Common Criteria NDPP+TFFW EP + VPN EP | Yes (with Junos OS 12.1x46) | Yes (with Junos OS 12.1x46) | Yes (with Junos OS 12.1x46) |
ICSA Network Firewall | Yes | Yes | Yes |
ICSA IPsec | Yes | Yes | Yes |
USGv6 | Yes (with Junos OS 12.1x46) | Yes (with Junos OS 12.1x46) | Yes (with Junos OS 12.1x46) |
Dimensions and Power |
Dimensions (W x H x D) | 17.45 x 8.7 x 24.5 in | 17.5 x 14 x 23.8 in | 17.5 x 27.8 x 23.5 in |
(44.3 x 22.1 x 62.2 cm) | (44.5 x 35.6 x 60.5 cm) | (44.5 x 70.5 x 59.7 cm) |
Weight | Fully configured 128 lb (58.1 kg) | Fully Configured: 180 lb (81.7 kg) | Fully Configured: 334 lb (151.6 kg) |
Power supply (AC) | 100 to 240 VAC | 100 to 240 VAC | 200 to 240 VAC |
Power supply (DC) | -40 to -60 VDC | -40 to -60 VDC | -40 to -60 VDC |
Maximum power | 4,100 watts (AC high capacity) | 4,100 watts (AC high capacity) | 8,200 watts (AC high capacity) |
Typical Power | 1540 watts | 2440 watts | 5015 watts |
Environmental |
Operating temperature – long term | 41° to 104° F (5° to 40° C) | 41° to 104° F (5° to 40° C) | 41° to 104° F (5° to 40° C) |
Operating temperature – short term8 | 23° to 131° F (-5° to 55° C) | 23° to 131° F (-5° to 55° C) | 23° to 131° F (-5° to 55° C) |
Humidity – long term | 5% to 85% noncondensing | 5% to 85% noncondensing | 5% to 85% noncondensing |
Humidity – short term8 | 5% to 93% noncondensing but not to exceed 0.026kg water/kg of dry air | 5% to 93% noncondensing but not to exceed 0.026kg water/kg of dry air | 5% to 93% noncondensing but not to exceed 0.026kg water/kg of dry air |